Items Description Output power:1500w Output power adjustment range:10-100% Laswer wavelength :1080±10nm Power consumption (including water cooling ):<1% Power stability:20kHZ laser response time:<10us Indication laser power range <1mW Type:Handheld Welding Torch with Wirefeeder Collimating focal length:50mm Focal length:150mm Fiber length:10m Cooling method:Water cooling Ambient temperature:10-40° Input voltage:220±10%Vac Power consumption ( including water cooling ):≤8KW Humidity:10-85% With FDA approval Multi Use: suitable for welding stainless steel, mild steel, aluminum and other metal materials (suitable for welding stainless steel, mild steel, aluminum and other metal materials.) The package includes Fiber Laser Welding+Auto Wire Feeder Product Specifications 1.rd human body. 2. Torch heBefore operation laser must wear with protection glass. Can't look straight the laser and touch the laser. Can't turn the torch head towaad can't be put upwards at any To prevent the dust enter into torch and pollute the torch head. Fragile and can't be falled. Be sure to keep it stable when not in use. If the power is reduced or the laser is not concentrated during welding, please stop using and check. (Usually, the protective lens may need to be replaced. ) Avoid further damage to the inside of the welding gun caused by laser scattering. Do not touch the interior of the chassis to prevent electrical shock. (1. You must wear the protective glass before operating the laser. 3. Do not look directly at the laser and touch the laser. Do not turn the torch head towards the human body. 4. The torch head must not be turned upwards at any time. To prevent dust from entering the torch and contaminating the torch head. 5. There are optical parts inside the torch. It is fragile and should not be dropped. Be sure to keep it stable when not in use. 6. If the power decreases or the laser is not concentrated during welding, please stop using and check. (Usually, it may be necessary to replace the protective lens). 7. Avoid further damage to the inside of the torch due to laser scattering. 8. Do not touch the inside of the case to prevent electric shock. (Hours.) Add coolant 1) Open the front door, pull out the water pipe plug and add coolant. Distilled water or purified water shall be used. Mineral water or filtered tap water are not allowed to used. 2)Make sure that the coolant is added to the range of “NORMAL”. If the machine has been moved or has not been used for a long time, reconfirm that the coolant is within the normal range. 3)In order to prevent the blockage of the pipeline caused by the growth of microorganisms and molds in the water in the chiller, it is recommended to replace the coolant once every two months to ensure the quality of the coolant. 4)When the ambient temperature of the equipment is below 5℃, ethylene glycol solution with a volume ratio of not less than 30% must be used and replaced every 2 months. 5)Working environment temperature of laser welding machine: 10 ℃ – 40 ℃; Working environment humidity: 10% - 85%; In order to ensure a good operating environment for the laser welding machine and reduce the probability of failure caused by condensation. It is strongly recommended that the laser welding machine be placed in an air-conditioned room with a temperature ≤ 30 ℃ and a relative humidity ≤ 70%. 6)Please pay attention to the danger of condensation: do not let this product work below the ambient dew point temperature. As shown in the following table, it cannot work in the dark area at the lower right corner, that is, the temperature difference between the cooling water and the ambient temperature cannot be too large. 7) If the laser is not used for a long time, the cooling water inside the cooling system and the laser should be drained, otherwise it may cause irrecoverable damage to the laser equipment. 8) Do not operate without water: please ensure that the water tank is filled with water before starting, otherwise the water pump is very easy to be damaged. It is strictly prohibited to use the circulating pump for drainage. 9) The filter screen at the air inlet must be cleaned regularly. Severe blockage of the dust screen will cause the failure of the chiller. (1) Open the front door, unplug the hose and add coolant. Distilled or purified water should be used. Mineral water or filtered tap water is not allowed. 2) Make sure coolant is added to the "NORMAL" range. If the machine has been moved or not used for a long time, make sure again that the coolant is in the NORMAL range. 3)In order to prevent the water in the cooler from breeding microorganisms and mold that cause clogging of the pipes, it is recommended to replace the coolant every two months to ensure the quality of the coolant. 4)When the ambient temperature of the equipment is lower than 5℃, the glycol solution with a volume ratio of not less than 30% must be used and replaced once every 2 months. 5) The working environment temperature of the laser welding machine: 10℃-40℃; working environment humidity: 10%-85%; In order to ensure that the laser welding machine has a good working environment and reduce the probability of failure caused by condensation. It is highly recommended that the laser welding machine be placed in an air-conditioned room with a temperature ≤ 30°C and relative humidity ≤ 70%. 6) Please note the danger of dew condensation: Do not allow this product to work below the ambient dew point temperature. As shown in the table below, it cannot work in the dark area in the lower right corner, that is, the temperature difference between the cooling water and the ambient temperature cannot be too large. 7) If the laser is not used for a long time, the cooling system and the cooling water inside the laser should be drained, otherwise it may cause irrecoverable damage to the laser equipment. 8)Do not operate without water: Make sure the water tank is filled with water before starting, otherwise the pump can be easily damaged. It is strictly forbidden to use the circulation pump for draining. 9)The filter screen of the air inlet must be cleaned regularly. (Severe blockage of the dust net will lead to the failure of the chiller.) Note WARM SERVICE & Lifetime after-sales service:Every single of our welder machines passed various authoritative Laboratory tests in simulating extremely harsh environments before leaving our DMC factory that conforms to the high standards. We take care of our customer's safety based on over current/over voltage/over current/over-load/overheating protection function. extremely harsh environments and meet high standards. Based on the over-current/over-voltage/over-current/over-load/overheating protection function, we take care of our customers' safety.) Important : If you have any problems, please contact the customer service. We will solve them for you and be responsible for you. Don't open the return at will or choose the wrong reason for return, and don't leave bad comments at will. We believe we can solve it for you Warranty: 2 years. If you have any quality problems, please contact us On May 5, 2023 at 21:06:28 PDT, seller added the following information: On Oct 9, 2023 at 01:29:25 PDT, seller added the following information:
Returns Accepted for this item if it's within 30 Days