· We ship to confirmed address only, no PO BOX,
NO exceptions!!! · Payment within 5 days of auction end · Signature is required for delivery · Buyers; we do not
rent equipment , please be sure to purchase to own (there will
be no return accepted unless DOA) · Bid only if you accept these terms This is a used Miyachi Unitek spot welder.
This unit came from an electronic company with clean room environment. Welder
is in good condition, comes as you see on photos, controller, transformer, cable, what you see is what you will get. Unit has been tested and performs as new. These
type of welders sell for over $7K new, this is your chance to own it for a
great price. MT-510A Welding Transformer CHARACTERISTIC Specification
/ Rating · MT-Rated Primary
Voltage 220Vac, ±10%, 50/60Hz · Rated Secondary
Voltage (without load) OFF,1.2, 1.8, 2.5, 3.5V · Current (maximum) 1.6
kA · Duty Cycle (maximum)
4% · Rated Capacity at
Duty Cycle 1.6 kVA · Input Peak Capacity
(max) 5.6 kVA · Insulation Voltage 3
kVac for 1 minute Physical: · Height 195 mm (7.68 in.) · Width 193 mm (7.6 in · Depth 288 mm (11.34
in) · Weight 20 kg (44 lb) ME-35A Weld
controller Input
Power Line Voltage Range 220 Vac ±10%, 50/60 Hz single phase Output
Energy (maximum) at 10% Duty Cycle 20
kVA ME-35A
Welding Control Power Consumption (maximum) 5W PHYSICAL Dimensions
(excluding terminal strip and Welcard projections: Height 269 mm (10.5 in.) Width 142 mm (5.5 in) Depth 330 mm (13.0 in.) Weight
5
kg (11 lb) ELECTRICAL Number
of Weld Schedules Stored in Memory 7 RMS
Primary Current: Maximum 90 A Minimum 5 A Feedback
Control Modes: Primary
Constant Current, Secondary Constant Current, Voltage Compensation,
Single Cycle Primary
Constant Current Mode: Initial
Feedback Response Rate (maximum time required for current to come
within ±10% of
current setting following
start of welding)
3 cycles Feedback Control
Rate (maximum) 1
cycle Current
Accuracy (minimum) over a ±10% fluctuation in input power line voltage
or over a
±30% variation in
welding resistance ±2% Currents 1
and 2 operating
range (10 A
resolution) . 0.2 to 8.0 kA Current
Range Limit (100 A resolution) 0.5 to 8.0 kAAPPENDIX A: TECHNICAL
SPECIFICATIONS ME-35A
FINE SPOT WELDING POWER SUPPLY Current
Monitor Operating Range: Upper Limit
(0%=OFF) +1 to
+49% Lower Limit
(0%=OFF) -1 to -49% Squeeze
Period (SQ) 0 to
99 cycles First Upslope
Period (UP1) (included
as part of
the Weld 1 period) 0
to 9 cycles First Weld Period (W1) .
0 to 99
cycles Cool Period
.0 to 99
cycles Second
Upslope Period (UP2) (included as part of the Weld 2 period) 0
to 9 cycles Second
Weld Period (W2) 0 to 99
cycles Hold Period
(HO) 0
to 99 cycles Pulsation 1
to 9 complete
Weld 2 periods Secondary
Constant Current Mode: Initial
Feedback Response Rate (maximum time required for current to come
within ±10% of
current setting following
start of welding)
2 cycles Feedback Control
Rate (maximum) 0.5 cycle Current
Accuracy (minimum) over a ±10% fluctuation in input power line voltage
or over a
±30% variation in
welding resistance ±2% Currents 1
and 2 operating
range (10 A
resolution) 0.2 to 8.0 kA Current
Range Limit (100 A resolution) 0.5 to 8.0 kA Current
Monitor Operating Range: Upper Limit
(0%=OFF) +1 to
+49% Lower Limit
(0%=OFF) -1 to
-49% Squeeze
Period (SQ) 0 to 99
cycles First Upslope
Period (UP1) (included
as part of
the Weld 1 period) 0
to 9 cycles First Weld
Period (W1) 0
to 99 cycles Cool Period
0 to 99
cycles Second
Upslope Period (UP2) (included as part of the Weld 2 period) 0
to 9 cyclesAPPENDIX A: TECHNICAL SPECIFICATIONS Second
Weld Period (W2) 0 to 99
cycles Hold Period
(HO) 0 to
99 cycles Pulsation 1
to 9 complete
Weld 2 periods Voltage
Compensation Mode: Feedback Control
Rate (maximum) 1 cycle Current
Accuracy (minimum) over a ±10% variation in input power line voltage
when welding at a 34%
power factor ±3% Currents 1
and 2 operating
range (1% resolution)
0
to 99% Current
Monitor Operating Range: Upper Limit
(0 KA=OFF) 0.2 to 8.0 kA Lower Limit
(0 KA=OFF) 0.2 to 8.0 kA Squeeze
Period (SQ) 0 to
99 cycles First Upslope
Period (UP1) (included
as part of
the Weld 1 period) 0
to 9 cycles First Weld
Period (W1) 0
to 99 cycles Cool Period
0 to 99
cycles Second
Upslope Period (UP2) (included as part of the Weld 2 period) 0
to 9 cycles Second
Weld Period (W2) 0 to 99
cycles Hold Period
(HO) 0 to
99 cycles Pulsation 1
to 9 complete
Weld 2 periods Single
Cycle Mode: Feedback Control
Rate None Current Operating
Range 0 to 99% Current Monitor
Operating Range, Upper/Lower
Limit (0 KA=OFF)
0.2 to 8.0 kA Squeeze
Period (SQ) 0
to 99 cycles Positive
Half (+HALF)\ Negative Half (-HALF) Cycle Weld Period 0.5
cycle Hold Period
(HO) 0 to
99 cyclesAPPENDIX A: TECHNICAL
SPECIFICATIONS Welding
Transformer Secondary to Primary Turns Ratio, Valves 1 and 2 1.0 to 199.9 External
Power Requirement for Valve Drivers 1 and 2 24-115 Vac Current
Step-Up, Steps 1 to 5: Step-up rate
based on value
of step 1,
in increments of
1% 0
to 99% Number of
welds per step 0 to 9999 Welcard
(Optional) Functions: Welcard
Schedule Card Capacity 91 weld
schedules (7 schedules,
13 files/schedule) Welcard
Monitor 1 Card: Parameters Stored
Start No., Step No., Current 1 and Current 2
values, Time Number of
Parameters Stored (max) 3,584 Welcard
Monitor 2 Card: Parameters Stored
Start No., Monitored Current ±%, Time Number of
Parameters Stored 7,168